Coil

• Ø5/8” copper tube.
• “V” type aluminum fins.
• The finned coils are designed with a/uminum fins spaced at 10 or 12 mm,
crimped onto copper tubes.
• Header in/et and out/et tube connections made of copper.
• Maximum operating pressure 21 bar.
• Staggered copper tubes.
• Low refrigerant charge required circuit design.
• The coil circuits are designed far refrigerants R404A, R449A, R22.
• Refrigerant distributor.

Casing

• Electrostatic powder coated RAL 9016 galvanized steeL
• Stainless steel and aluminum casing as optionaL
• Side panels are removable.
• Hinged/Folding drain tray is standard for ali models.
• lntermediate drain pan.

Fan

• Selection of a unit cooler with various fan number/diameter combinations
offering the dimensional and air throw characteristics besi adapted to
the size of the cold room.
• Selections should be confırmed by your Buzçelik Technical Specialist.
• Standard or low noise level are available.
• Different kinds of motors available as optionaL (EC or AC)
• Motor protection IP54 insulation class F.
• Different kinds of accessories available as optionaL (Axicool Fans,
FlowGrid etc.)
• Working conditions -40”C/+50”C.

Defrosting

• Products have 82 type defrost system and spare defrosts.
Oefrost heaters are applied on both heat exchanger coil and drain tray.
• Drain /ine heaters, fan housing heaters and hot gas defrost system are optional.
• This facility enab/es homogenous heat distribution far fast and efficient
defrosting.
• A water defrost (WD) option is available far room temperature equal to or greater
than +4° C. in this case the unit coo/er depth is increased amount of depth.
- B2 (Optiona/) : Electric defrost (coil + drain pan)
- HGD (Optiona/): Hat gas (coil and drain pan)

Capacity

The nominal capacities calculated according to Eurovent EN328 standards
that refer to E.T./R.T=-40°C/-34 °C condition and are valid far R404A.

Options

• Different casing color.
• Other tube wall thicknesses and fın spacing on request.
• Mono phase 220V 1 ~ 50Hz fan or three phase 400V 3~ 50Hz fan.
• Please keep in touch with our sales department about your special needs
that are not mentioned in the catalogue.

Note

Please read “lnstallation, Operation and Maintenance lnstructions” for
mounting and maintenance.

Accessories

• Hol gas defrost in coil and drip tray.
• lnsulated drip tray.
• Casing made of stainless steeL
• Epoxy resin coated aluminum fıns.
• Fan cable heaters.
• Drain line cable heater.

Would you like to get industry-related information faster?