Oem Finned Pack Heat Exchangers
According to technical specifications, the OEM orders are produced.
Capacities of CONVECTOR COILS for 90 °C / 70 °C are between 336 W - 11200 W. Dimensions are min: 600 mm - max: 3000 mm.
DUCT HEATING AND COOLING COILS have such properties: » Class A,B and C Leakage Performance according to EN 1751 » Easy assembling with rectangular or circular connection flanges » Special fin or casing material options are available » Stainless steel drip trays for duct cooling applications
Aluminium tube and aluminium fin heat exchangers for lighter weight and easy mounting.
The headers of steam coils are made of carbon steel. Tube thickness can be up to 1mm for steam coils produced with copper tubes in high pressure applications. Connections are external threaded as standard or with flanges on request. All headers are provided with vent and drain fittings. Sliding collars and free holes system combination are used i...
The headers of hot / cold water coils are made of carbon steel and for hygiene coils they are made of copper. Connections are external threaded as standard or with flanges on request. All headers are provided with vent and drain fittings. Sliding collars and free holes system combination are used in end sheets.The water coil rating in this catalo...
For AIR COOLERS FOR SHOP WINDOWS capacites are between 54 W - 5100 W. Finned length are minimum 500 mm maksimum 4000 mm.
For WATER-GLYCOL DUAL DISCHARGE COOLERS,capacities are between 1560 W - 64438 W. It has 5 different series GDDA, GDDH, GDDM, GDDAQ, GDDHQ.
For WATER-GLYCOL standart UNIT COOLERS, capacities are between 2093 W - 76940 W. It has 4 different series GCA, GCH, GCAQ, GCHQ.
• FRITERM Blast Freezers, including H series, S series, T series and K series, are designed to meet all needs of blast freezing applications from 6,2 kW to 56,7 kW based on -35°C room and -40°C evaporation conditions. In FSL T Serie BLAST FREEZERS capacities are between 8,3 kW - 62,7 kW. • Fin spacing is 12 mm for all model....
• FRITERM Blast Freezers, including H series, S series, T series and K series, are designed to meet all needs of blast freezing applications from 6,2 kW to 56,7 kW based on -35°C room and -40°C evaporation conditions. In FSL K Serie BLAST FREEZERS capacities are between 17,4 kW - 70,5 Kw. • Fin spacing is 12 mm for all model...
• FRITERM Blast Freezers, including H series, S series, T series and K series, are designed to meet all needs of blast freezing applications from 6,2 kW to 56,7 kW based on -35°C room and -40°C evaporation conditions. In FSL H Serie BLAST FREEZERS capacities are between 8,5 kW - 47,8 kW. • Fin spacing is 12 mm for all model....
• FRITERM Blast Freezers, including H series, S series, T series and K series, are designed to meet all needs of blast freezing applications from 6,2 kW to 56,7 kW based on -35°C room and -40°C evaporation conditions. In FSL S Serie BLAST FREEZERS capacities are between 8,5 kW - 53,4 kW. • Fin spacing is 12 mm for all model....
• FES model ceiling type unit coolers are specially designed for small, medium and large industrial cold room, frozen storage, blast freezing and rapid cooling room applications. • Friterm FES series are ceiling mounted, single side discharge evaporators draws air across the coil. • Unit coolers with three phase motors are availabl...
• Ceiling type unit coolers are specially designed for small, medium and large cold room and frozen storage room applications with a wide range capacity from 0,2 kW to 47,55 kW. Besides, it has 3 different noise levels of standart, medium noise level (M) and low noise level(L). In VERY LOW SPEED DUAL CROSS COOLERS, capacities are between1...
• FEDD model ceiling type unit coolers are specially designed for small, medium and large cold room, frozen storage room applications with a wide capacity range from 0,8 kW- 97,8 kW. Besides, they have 2 fan types for different noise levels of standart (s) and low noise level (L). • Friterm FEDD serie are standart double side discharge, ...
• FEWR model ceiling type unit coolers are specially designed for small and medium size cold room,frozen storage room applications with a wide capacity range from 0,5 kW - 24,8 kW. Besides, they have 2 fan types for different noise levels of standart (s) and low noise level (L). • Friterm FEWR types are standart single side discharge, bl...
• Ammonia coolers are specially designed for medium and large industrial cold room, frozen storage ,blast freezing and fast cooling room applications. • Friterm NES ceiling mounted single discharge evaporators draws air across coils . • Triphase fans provides coolers to be suitable for not only fast cooling but also low air circula...
STARBOX Condenser Unit models are designed in 2 main series which are STARBOX - N (Normal series), STARBOX - T (Tropical series). It's also ideal for long lasting outdoor installation of all applications in refrigeration and air conditioning. Besides, it has 2 different noise levels of (S) Standart and (L) Low Noise As a standard the s...
• Friterm FCH/FCV series condensers are designed for outdoor installation, including 4 different sound levels. No external pressure drop is considered. • The fans arranged in single rows from 1 to 4 and in double rows from 2 to 14. • Capacity range: 11 to 1428 kW. • All models are available with vertical or horizontal airflow...
• Friterm FCW series condensers are designed for outdoor installation including 4 different noise levels. No external pressure drop is considered. • The fans arranged in single rows from 2 to 10 and in double rows from 4 to 20. • Capacity range: 78 to 2095 kW
• Friterm FCV 3T series condensers are designed for outdoor installation including 2 different sound levels. • The fans arranged in single rows from 1 to 3. • Capacity range: 6.3-69 kW.
In adiabatic cooling pad systems, cool pads are placed in special sheet metal assemblies which are mounted in front of fin block. With the aid of the pump, water wets the pads from the upper part of the pad system. The outside air, which is dry and hot, is pre-cooled by passing it through wet cooling pads. The temperature of the air that contact wi...
Fogging spray system provides adiabatic cooling effect which is provided via intermittent fog spray on incoming air stream of heat exchanger. System comprises several spraying equipments and a series of specialized water nozzles, designed to pulverize the water (35 micron) at high pressure (70 bars). In this system strict water treatment is require...
Ecomesh Spray System concept is based on intermittently and effciently evaporating water on a large mesh area in front of the heat rejection surface of Dry Coolers. Water spray provides an adiabatic cooling effect of the incoming air stream. As a result of indirect water spray system, lins are not defected by water calcareous which is prevented by ...
Direct adiabatic water spray system provides adiabatic cooling effect which is provided via intermittent water spray on incoming air stream of heat exchanger. System comprises several spraying equipments and a series of specialized water nozzles, designed to pulverize the water. In this system strict water treatment is required.
• Friterm FDW series dry coolers, including 4 different sound levels of - (S) Standard, - (L) Low, - (Q) Quiet, - (E) Extremely Quiet, are designed for outdoor installation. • The fans are arranged in single rows from 2 to 10 and in double rows from 4 to 20. • Capacity range of Dry Coolers varies fr...
• Friterm FDH/FDV series dry coolers, including 4 different sound levels of - (S) Standard, - (L) Low, - (Q) Quiet - (E) Extremely Quiet, are designed for outdoor installation. • The fans are arranged in singl...
The headers of oil cooler coils are made of carbon steel, copper or stainless steel. Connections are external threaded as standard or with flanges on request. Turbulator can be equipped into the tubes depending on design for increasing oil cooler efficient.
Optimum solutions for reducing engine - turbine systems’ cooling water temperature Made of high corrosion resistant materials assuring long operation life in corrosive ambient High efficient products thanks to use of high production technology and high quality materials Performance Guaranty by Friterm Design Software, approved by acc...
Optimum solutions for turbine-generator systems’ combustion inlet air cooling used in the Energy Sector Manufactured as packaged unit consist of highly efficient cooling coil, air filter and drop eliminator Made of high corrosion resistant materials assuring long operation life in corrosive ambient High efficient products thanks to u...
Contrary to heat pipes, plate heat exchangers (recuperators) and rotary heat exchanger (regenerator) no junction of the air flows is required at the bildings energy recovery system for coil energy recovery loop systems. Through the absolute separation of extract air flow and outdoor air flow the coil energy recovery loop system is the firs choice f...
• This system provides a significant benefit when dehumidifying air to lower its temperature and reheat it not to deliver too cold air into the conditioned space. • Heat pipe facilitates the applications when dehumidification is needed and increases system efficiency. • It enhances indoor air quality. • Heat pipe can be manuf...